SERVICE AND ASSESMENT INCLUDES THE FOLLOWING:
Preparation for maintenance:
> Service data and HACCP data are saved on the USB stick
> Current software available on the unit
> No service errors or gas errors in the service history
Maintenance for unit door:
> Unit door and door glass as well as door settings OK
> Door seals and possibly mobile oven rack seal undamaged
Examination of the cooking cabinet:
> All cooking cabinet components undamaged, correctly installed and operational
Maintenance of the water connection/drain:
> No fat/no pollution in the waste water connection
> Complete water distribution tight, water inlet filter clean and valves operational
> All pumps and add-on components operational and tight
> Control box with all components operational and clean
Maintenance of the steam generator:
> Steam generator and all associated components operational
> Steam generator steam hose to the cooking cabinet and pump-off hose are operational and tight
Maintenance of the electrical system:
> Electrical wiring fault-free (terminals tight and no damaged insulation)
> Steam and convection heating operational
> Enter the maximum board temperature in the comments field
Maintenance of the control panel:
> Control panel operational and tight
> All control panels without damage and operational
Maintenance of the exhaust hood/UltraVent:
> All fat filters installed and clean
> Enter the clearance between the top edge of the unit and the bottom edge of the exhaust hood/top panel in the comments field
Maintenance of the rollers and wheels:
> All rollers and wheels of the stand, the mobile oven racks or the Combi-Duo are securely tightened and without damage.
Instructions for unit care:
> Instructions for the iCare System
Instructions for housing maintenance:
> Explain replacement of filter and door seal.
> Descaling of the steam control nozzle
Checking electrical safety:
Electrical safety (leakage current, insulation and earthing) tested in accordance with local standards and legal regulations.
Warning gas components:
Gas components/gas connections tight and operational
External gas interlock system operational and tested
> Flue gas test carried out and values within the permitted range